Model guide · EcoFlow
EcoFlow DELTA Pro 3: what can it run?
A 4,096Wh portable power station with a 4,000W AC inverter. It can start a full-size fridge and run one for an estimated 36h–56h.
Estimated AC runtime by device
Ranges use the low and high watt loads in our device data, from a full charge. They are planning estimates, not measured results for this model.
| Device | Load while running | Estimated runtime |
|---|---|---|
| Wi-Fi router | 8–20W | 115h–191h |
| Laptop, charging and active | 30–90W | 35h–87h |
| Full-size fridge | 150–250W · 35% duty cycle | 36h–56h |
For the fridge, the 1,200W startup assumption fits within this unit's 6,000W surge rating. Real fridge demand and cycling vary. A router may run longer from a compatible DC output, which this AC table does not model.
The specs that matter
- Battery: 4,096Wh LiFePO4, with an estimated 3,482Wh usable through AC at a moderate load, before idle draw.
- AC output: 4,000W continuous and 6,000W surge. Check the startup draw of motor loads.
- Weight: 113.5 lb.
- Cycle claim: EcoFlow states 4,000 cycles to at least 80% capacity. That is a battery-life claim, not a runtime promise.
On Sep 24, 2026, EcoFlow listed an 8,000W AC surge output for momentary spikes. This page uses the lower 6,000W X-Boost rating, which the unit can sustain.
On Sep 24, 2026, EcoFlow listed a transfer time of 10 ms for its backup function. Test your actual router, PC or NAS through a mains-loss simulation before relying on it for uninterrupted operation.
Where the estimate can miss
This model has no published AC idle-draw measurement, so the calculation uses 12W (est.). Idle draw matters most for a small load such as a router. Inverter efficiency is our class default. Temperature, battery age, output mode and the actual device load can all move the result.
The stated surge rating tells you what the inverter is designed to accept. It does not measure your fridge's startup spike. For essential equipment, measure the load and run a full-duration test.
Nearest models by capacity
The closest smaller and larger models with a guide on this site. Fridge estimates use the same 150–250W load and 1,200W startup assumption as the runtime table on this page.
| Model | Rated capacity | AC output | Full-size fridge |
|---|---|---|---|
| Jackery Explorer 2000 v2 | 2,042Wh | 2,200W | 17h–26h |
| EcoFlow DELTA 2 Max | 2,048Wh | 2,400W | 18h–27h |
| Anker SOLIX C2000 Gen 2 | 2,048Wh | 2,400W | 17h–26h |
| Bluetti Elite 200 V2 | 2,073.6Wh | 2,600W | 19h–30h |
Product prices and availability are accurate as of the date/time indicated and are subject to change. Any price and availability information displayed on Amazon at the time of purchase will apply to the purchase of this product. As an Amazon Associate we earn from qualifying purchases.